CT-1 is a portable measurement device specially used for detecting single-phase AC quality, and it can be easily used to observe voltage harmonic wave and interference noise (THD+N) as well as the size of and the change along with time in DC weight arising from asymmetrical waveforms of circuit voltage. Through measurement without interruption, CT-1 can also enable the observers to see the status on changes in AC quality in different time periods of a day (This is a strong proof to reveal that the sound quality at midnight is obviously better than that in the peak power consumption period of dusk.), and to listen to music by avoiding the period of high power pollution.
By using CT-1, AV fanciers can easily find the problems with AC quality and solve them by selecting and using proper power processing devices, so that the existing apparatus can again show their original satisfactory performances.
The values of voltage harmonic waves and interference noises (THD+N) measured by CT-1 can also be sent to the driven earphone or the monitoring port connected with oscillograph and other devices in addition to pointer indication, for direct monitoring of the relative sizes of harmonic wave and interference noise components or for further observation and measurement analysis with oscillograph.
The indication value (full scale) of CT-1 for measurement of voltage harmonic wave and interference is ranged at 5%, corresponding to the value of allowance in governmental standard, and when THD+N exceeds 5%, the meter pointer will be offset beyond the reading range, to show that AC quality has grievously deteriorated.
In addition to precision reading, the measurement value of CT-1 can also be rapidly and visually used in different color zones of meter to represent degrees of impact from AC quality on AV apparatus. When DC weight is measured, the transformer of audio equipment is normally quiet if pointer is located inside the green zone, while the pointer is turned to the red zone, the noise of vibrations with most large-power IR transformers reaches to an easily audible degree. Therefore when users of apparatus find noise of vibration exists with the apparatus, CT-1 can help the owner of the apparatus easily determine whether or not the noise is initiated by DC in the power supply.
CT-1 can also be used to detect and sense the sources of noises in the power circuit, or to compare the status on changes in AC quality before and after processing by power processing devices.
High-sensitivity CT-1 can measure the lowest readable value of THD+N as low as 0.5%, and its measurement resolving power for DC weight can reach 20mV. Rational and precision functional design and the method for representation of AC quality by different color zones have enabled the measurement of AC quality by CT-1 to be very simple and visual.
CT-1 can help AV fanciers to find problems with AC quality, select and use power processing devices, and verify their reachable actual efficacies based on scientific measurements.
To maximize the performance of Hi-end systems, it is an extremely important basic condition to ensure an accurate voltage and a pure waveform, and CT-1 no doubt is a top-choice tool necessary for AV fever friends to test AC quality.
The power consumption of CT-1 itself is extremely low (smaller than 1W), can serve as a perennial device for continuous use always in synchronized operation with AV apparatus, so that you can readily know about the changes in original AC quality and whether or not power processing devices are operating under normal condition.
When CT-1 is put into synchronized use (in the common frequency of urban power supply) with power processing devices with known smaller THD+N, it is also able to indirectly monitor as to whether or not the frequency drift of AC frequency (50Hz) is larger than the international lowest allowance of 0.5Hz through judging whether or not the indication value for measurement of THD+N is offset beyond the normal reading range. |